Buffalo LinkStation 421 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro NAS a úložné servery Buffalo LinkStation 421. Buffalo LinkStation 410 Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 87
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
LS400 Series
User Manual
www.buffalotech.com
35013107-03
2013-11
Zobrazit stránku 0
1 2 3 4 5 6 ... 86 87

Shrnutí obsahu

Strany 1 - User Manual

LS400 SeriesUser Manualwww.buffalotech.com35013107-032013-11

Strany 2 - Contents

103 Changing the password from the default is recommended.Note: You can open this same screen by clicking Getting Started from Easy Admin.4 Enter th

Strany 3

11Chapter 2 ConfigurationConfigure and administer your LinkStation using the Settings interface, accessible from a browser window. Open the interface

Strany 4

12Notes: • If you click any buttons, you will need to enter a username and password.• Username/Password Combinations:Username Password Settings Avai

Strany 5

13Refer to “Installation” for more details.WebAccessConfigure WebAccess settings to remotely access your LinkStation.Refer to “WebAccess” for more det

Strany 6

14Refer to “DLNA” for more details.USB Device ServerConfigure USB device server options.Refer to “USB Device Server” for more details.Opening Advanced

Strany 7 - Chapter 1 Installation

15Note: To go back to Easy Admin, click the Home icon.

Strany 8 - Installation

16Chapter 3 Remote AccessWebAccessWebAccess is a program for accessing the files in the shared folder of your LinkStation from your computer, smartpho

Strany 9

172 Move the WebAccess switch to the position to enable WebAccess.3 Select the level of access for each shared folder from the drop-down list.4 E

Strany 10

183 Configure the desired settings, then click OK.• To use SSL encryption for more secure data transfers, enable “HTTPS/SSL Encryption”.• Some WebA

Strany 11 - Chapter 2 Configuration

19• When accessing shared folders through WebAccess from a remote location, the username and password may be required for certain operations. For bes

Strany 12 - Getting Started

2ContentsChapter 1 Installation ...7Diagrams ...

Strany 13 - BitTorrent

20WebAccess AccountNot logged in R R - - - -User with read & write accessR/W R R/W R R/W RUser with read-only accessR/W R R/W R R RGroup with read

Strany 14 - USB Device Server

21Accessing the LinkStation with an FTP client• To access the LinkStation via FTP, configure your FTP client software with the following settings:Hos

Strany 15

22• To allow anonymous access to your FTP share, disable access restrictions.• To access the LinkStation via anonymous FTP, configure your FTP clien

Strany 16 - Chapter 3 Remote Access

23Chapter 4 Access RestrictionsYou may restrict access to specific shared folders, including external USB drives.Notes: • Access restrictions can be

Strany 17

24Notes: • Names may contain up to 27 alphanumeric characters, hyphens (-), and underscores (_). Do not use a symbol as the first character in a name

Strany 18 - 4 Click OK

25Read-only SharesBy default, new shares are set with read & write access, but you may change the attribute to “Read-only” in “Shared Folder Attri

Strany 19 - 8 Click Edit

26• The user ID should be a number from 1000 to 1999. Each user ID should be unique. If this field is left blank, a user ID is assigned automatically

Strany 20

27Notes: • Group names may contain up to 20 alphanumeric characters, hyphens (-), underscores (_), and periods (.). Do not use a symbol other than an

Strany 21

283 Click Edit.4 Enable “Access Restrictions”.5 Select the level of access for the user or group you added.: Read and write access allowed

Strany 22

29(where # is a number, for example: usbdisk1)• Don’t use the following unsupported characters in shared folder names, workgroup names, or filenames:

Strany 23 - Chapter 4 Access Restrictions

3Adding a Shared Folder ...23Adding Users ...

Strany 24 - Accounts

303 Click Edit.4 Select “Active Directory”, then click Next.5 Click Yes.6 Enter the desired settings, then click OK.7 Choose Folder Setup.8 Clic

Strany 25 - 2 Click Create User

3112 Click OK.Notes: • If both read-only and read & write permissions are given, the user will have read-only access. The most restrictive access

Strany 26 - 2 Click Add Group

32Note: To use Active Directory from Windows 2000 or Windows Server 2003, select “Active Directory” instead of “NT Domain”.6 Click Yes.7 Enter setti

Strany 27 - Access Restrictions

33Notes: • If you change the LinkStation’s name, you will no longer be able to use domain users and groups or access restric-tions. To repair this, r

Strany 28 - 6 Click OK

345 Click Next.6 Enter a workgroup name. Select “Assign authorization to external SMB server” and enter the authentication server’s IP address (reco

Strany 29 - Active Directory

3512 Select the level of access:: Read and write access allowed : Read access allowed : Access prohibited13 Click OK.Notes: • If both rea

Strany 30

36Chapter 5 Managing StorageRAID ArraysThe default RAID mode is RAID 0.Notes: • If you change the RAID mode, all data on the array is deleted. This i

Strany 31 - NT Domains

372 Select RAID.3 Select the array to delete.4 Click Delete RAID Array.5 Step through the wizard to delete the array.Once JBOD is configured, crea

Strany 32

386 Click OK.7 Choose the array to configure.8 Select a RAID mode and the drives to be used, then click Create RAID Array.9 Step through the wizar

Strany 33 - 4 Select “Workgroup”

397 Click Create RAID Array. The “Confirm Operation” screen will open.8 Enter the confirmation number, then click OK.RAID ScanningRAID maintenance s

Strany 34

4Quotas for Users ...45Quotas for Groups ...

Strany 35 - 13 Click OK

40Store”. For best results, reformat the drive before using it as a backup target.• You can use the USB Device Server to connect a USB hub and up to

Strany 36 - Chapter 5 Managing Storage

412 Click the icon to the right of “USB Drives”.3 Select the drive to dismount and click Dismount Disk. The “Confirm Operation” screen will open.

Strany 37

424 Click Check. You have the option of deleting information files from Mac OS during the check if desired.Formatting DrivesNote: Under some circumst

Strany 38

434 Select a format type, then click Format.5 The “Confirm Operation” screen will open. Enter the displayed number, then click OK.6 Depending on th

Strany 39 - Adding an External Hard Drive

44• The following format types are supported: FAT32 (recommended for connecting to computers), EXT3 (recom-mended for sharing with other LinkStations

Strany 40 - Dismounting from Settings

45Disk QuotasNotes: • When using quotas, disable the recycle bin or empty the trash folder often. The limited space includes the space used for trash

Strany 41 - Checking Drives

464 Click Close.5 In Advanced Settings, click to the right of “Users”.6 Change the user’s primary group to the group with the quota, then click O

Strany 42 - Formatting Drives

473 Push the failed drive’s cartridge up and remove it from the LinkStation.Notes: • Do not press hard on the top of the LinkStation.• Pull the dri

Strany 43 - Formatting External Drives

487 Insert the new drive in the empty slot.8 Close the front panel.9 Connect all cables, then turn on the LinkStation.10 For RAID 0Navigate to Driv

Strany 44 - 3 Click Erase LinkStation

49Chapter 6 BackupBack Up from the LinkStationYou can back up LinkStation folders to:• A different folder on the LinkStation• Another LinkStation on

Strany 45 - Disk Quotas

5Setting Up a Printer with Windows XP ...66USB Device Server ...

Strany 46 - Hard Drive Replacement

50Note: To configure a password, enter it in the “Remote Backup Password” field. Leave this field blank if you don’t want a password. If the target de

Strany 47 - 6 Replace the four screws

514 Select the IP address of the LinkStation or TeraStation that you want to set as the backup target. Click Add, enter the IP address of the target

Strany 48 - 8 Close the front panel

523 Click Create New Job.Note: Up to 8 backup jobs can be configured.4 Select backup settings such as date and time to run.Note: The following types

Strany 49 - Chapter 6 Backup

537 Select the shared folder that will be the backup source, then click OK.8 Click Browse under “Backup Target Folder Name”.9 Select the backup tar

Strany 50

542 Choose Folder Setup.3 Choose a shared folder as your backup destination for Time Machine.4 Click Edit.5 Select AFP (Mac) from “LAN Protocol Su

Strany 51 - Configuring a Backup Job

5511 Click Browse.12 Select the shared folder that you set in the previous step, then click OK.13 Click OK.14 Click OK.15 Move the Time Machine switch

Strany 52 - 5 Click Add

5618 Click Choose Backup Disk.19 Select the LinkStation, then click Use for Backup.20 Enter a username and password with the rights to access the shar

Strany 53

57Copying from a USB DeviceUse Direct Copy to copy from a USB device directly to the LinkStation.Note: To use Direct Copy, connect only one USB device

Strany 54

58Chapter 7 MultimediaDLNADLNA is a set of guidelines for sharing digital media. The LinkStation includes a DLNA server compliant with the DLNA guidel

Strany 55

59Configuration from Advanced Settings1 Navigate to File Sharing - Folder Setup.2 Select the folder that you want to share with media players and ot

Strany 56 - 18 Click Choose Backup Disk

6Default Settings ...85Specifications ...

Strany 57 - Copying from a USB Device

609 Select an interval for DLNA server database updates and click OK.Play FilesTo play back content from a DLNA-compatible device:1 Connect the DLNA

Strany 58 - Chapter 7 Multimedia

61Streaming to DLNA-compatible DevicesWhen new movies, photos, and music files are added to the LinkStation’s DLNA folder, the database must be update

Strany 59

62Supported File TypesThe LinkStation supports DLNA streaming of files with the extensions below.Type File ExtensionsVideo Filesmpe, mpeg, mpeg2, mpg,

Strany 60

63BitTorrentBitTorrent is a protocol for distributing large amount of data efficiently. The information in this chapter is for users who are familiar

Strany 61

645 Select the shared folder where the downloaded file will be saved, then click OK.6 Enter the port number, then click OK.7 Move the BitTorrent sw

Strany 62 - Supported File Types

65• Don’t disable the SMB protocol while the printer server is enabled. If you do, you will need to enable SMB again and reconfigure the print server

Strany 63

669 Register the printer.Setting Up a Printer with Windows XP1 Connect a printer to the LinkStation’s USB port, then turn the printer on.2 In Advan

Strany 64 - Connecting a Printer

679 Register the printer.USB Device ServerThe USB device server lets you use USB devices connected to the LinkStation with multiple computers.Configu

Strany 65

68USB Device Server in Advanced Settings. You’ll need administrator privileges to install the software.Connecting with Network-USB Navigator1 Launch

Strany 66

69Chapter 8 Advanced FeaturesEmail NotificationYour LinkStation can send you email reports daily, or when settings are changed or an error occurs. Not

Strany 67

7Chapter 1 InstallationDiagramsLS410DLS420DLS421DE1 Power LEDThe white power LED is lit while the LinkStation is on.The white power LED blinks while

Strany 68 - Disconnecting USB Devices

70Sleep ModeTo save energy, you can specify times to put the LinkStation into sleep (standby) mode, where the hard drive and LEDs are turned off.1 In

Strany 69 - Chapter 8 Advanced Features

71Notes: • Up to three timers can be set.• The time to enter sleep mode can be set from 0:00 am to 3:45 of the next day.The time to wake from sleep

Strany 70

72Timer 2: Selected day of the week Wednesday 7:30-22:00Timer 3: Not usedOn days other than Wednesday, normal operation begins at 9:00 and the unit go

Strany 71

73the UPS and without the power supply restored, automatic shutdown is not performed, even after the specified time has elapsed.• If the power supply

Strany 72

74Online UpdateIf a new firmware is available, a message is displayed when the LinkStation boots. You can update the firmware by the following way:1

Strany 73 - Restoring Factory Defaults

755 Click the Time tab. Enable NTP server and check “Use Local Date/Time” to use your computer’s time settings for the LinkStation.By default, the Li

Strany 74 - Online Update

76Note: This tab changes the language used by the LinkStation for email notification, DLNA, and other functions. To change the language displayed in S

Strany 75

77Changing the IP AddressNormally, the LinkStation’s IP address is set automatically from a DHCP server on your network. If you prefer, you can set it

Strany 76 - 4 Click Edit

78Chapter 9 UtilitiesNAS Navigator2 for WindowsNAS Navigator2 is a utility program that makes it easy to display Settings, change the LinkStation’s IP

Strany 77 - Changing the IP Address

79Name DescriptionMenuMap Share*Assigns the LinkStation’s shared folder as a network drive.Disconnect Share*Unmaps the network drive.Map All Remote Sh

Strany 78 - Chapter 9 Utilities

85 Power SwitchMove the switch up and down to power on and off.6 USB 2.0 PortCompatible Buffalo USB hard drives, USB flash drives, digital cameras,

Strany 79

80Exit Exits NAS Navigator2.The following tasks may be performed from the LinkStation’s properties page.Name DescriptionConfiguration Click Settings t

Strany 80 - Mount as Network Drive

81any other hard drive.NAS Navigator2 for Mac OSNAS Navigator2 is a utility program that makes it easy to display Settings, change the LinkStation’s I

Strany 81 - NAS Navigator2 for Mac OS

82To display these options, hold down the control key and select your LinkStation’s icon.Open Folder Opens the LinkStation’s shared folder.Settings Op

Strany 82

83Chapter 10 AppendixWhen the Power LED BlinksWhiteThe power LED will blink white during bootup or shutdown.RedIf there is an error, the power LED wil

Strany 83 - Chapter 10 Appendix

84E22 Mounting of hard drive X failed.Format the hard drive. After formatting, if the error still appears after rebooting, replace the hard drive. If

Strany 84

85I28 Formatting USB hard drive. -I46Data migration or conversion (RAID migration) is in progress.Do not turn off the LinkStation power.I47Data migrat

Strany 85 - Default Settings

86SpecificationsCheck www.buffalotech.com for information about the latest products and specifications.LAN PortInterfaceIEEE 802.3ab (1000BASE-T)IEEE

Strany 86 - FCC Warning

87may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired opera

Strany 87 - Environmental Information

9• An autoplay screen may appear with Windows 8, Windows 7, or Windows Vista. Click Run LSNavi.exe then. If “A program needs your permission to conti

Komentáře k této Příručce

Žádné komentáře